Insulation class of motor pdf

However, premature failures of motor insulation systems began to occur as fastswitching, pulsewidthmodulated pwm vfds were introduced. At 160c 320f, the average life of the class n insulation would. Nema insulation classes for motors drives and automation. At c, the insulation resistance value after the motor has been rewound. Figure 4 insulation life versus temperature environmental contamination of the motor windings reduces dielectric strength dramatically. The temperature class of the insulation system is typically determined using the test methods outlined in underwriters laboratory standard ul 1446 systems of insulating materials general 8. The hotspot is a point at the center of the motors windings where the temperature is higher. Iec standards the motor standards can be grouped into two major categories. Based on a 40 degrees c ambient temperature, the class b insulation is suitable for 80 degrees c rise by resistance. There was a phase loss situation that would have ended up with the loss of a 200 hp motor if it hadnt been protected by littelfuse. It provides electrical separation between the energized windings and the outside housing of the motor, the endbell. It is important to be aware that insulation classes are directly related to motor life. Motors for use on a frequency converter without filter up to 500 v limit curve a for motors of the design series kv. In fact, electric motor and generator have an inherent capacity sufficient for.

If the motor is kept in a place with high humidity, a periodical inspection is necessary. Alternator winding temperature rise in generator systems. The electrical insulation system is sometimes referred to as insulation class or. Catalog high voltage engineered induction motors technical. Other materials or combinations of materials may be included in this class if by experience or tests they can be shown to be capable of operation at the class a temper. Each insulation class has a margin allowed to compensate for the motors hot spot. Insulation classes for electric motors learning electrical engineering. Over the years, after many cycles of operation, electric motors are exposed to environmental factors such as dirt, grease, temperature, stress, and vibration. Class f insulation maximum temperature rise of 80c by resistance 40c ambient altitude of meters or less. So if we look at a class f insulated motor which will be happy running at. Defining the thermal class of an alternator is not easy. Motor insulation temperature rise allowable for each class of insulation is always based upon an ambient of 40c which is the air on temperature to the motor for cooling purposes. Electric motor calculator calculate amps, hp and kva. The switching rates of modern power semiconductors can lead to voltage overshoots.

Alternatively the motor could be specified for an insulation class, but be design to run at a low class for example insulation class f, temperature rise b. How to measure electric motor insulation resistance custom search. How to measure electric motor insulation resistance. Electrical motors will rapidly degrade if the internal temperatures exceeds the insulation temperature limits. The correct insulation of the winding of a motor is determined by both the temperature rise in the motor and the temperature of the ambient air. The selection of induction motors designed to match the load requirements of any particular application need to ensure that the temperature inside the motor windings does not rise to a level that exceeds the critical temperature. Insulation class is indicated by a letter designation such as a, b, f or h see table 2, depending on the windings ability to withstand a given operating temperature for a given life. The insulation system isolates one winding turn from another.

The esp motor insulation should be class n or class s. Standard insulation class ratings for groschopps motors and. Increasing the temperature further to 155c class f insulation limit or 180 c class h insulation limit will further reduce insulation life. Class a insulation consists of materials such as cotton, silk and paper when suitably impregnated or coated or when immersed in a dielectric liquid such as oil. Class a motor slot insulation, made up of paperboard, insulates the. Electronic adjustable speed drives, known as variable frequency drives vfd, used to be marketed as usable with any standard motor. Class f insulation is suitable for 105 degrees c rise by resistance. Insulation life voltage service factor service factor unbalance 1.

At b, the sharp drop indicates an insulation failure. Given the ambient installation conditions, constructions to class h are optionally available, for which the respective overtemperature is permitted. All four classes identify the allowable temperature rise from an ambient temperature of 40 c 104 f. All ratings in this catalog are designed for the following. In general, if a motor runs cooler, it has a longer life. Usa motors temperature tolerance class f is the most common for international and 50 hz motors. A guide to measuring electric motor insulation resistance.

Insulation class standards established by the national electrical manufacturers association nema to meet motor temperature requirements found in different operating environments. Classes of insulation department of electrical engineering, iit. Thermal evaluation and classification of insulation systems used in rotating machines in this, the test samples are exposed to thermal, mechanical, electrical stresses, simulating the real environment, to approve the insulation system for application in harsh environments. Iec 600341 insulation class and temperature rise avsld. Electric motor manufacture design the winding insulation class depend on technical aspect and user application. It is made up of organic material such as paper, wood and varnish. The advantage of the second method is that there is an inherent 25 o c safety margin useful if you are in a region with high ambient temperatures or need to date the motor for some. So the engineer selects the electric motor based on applications and working area temperature characteristics. Groschopps standard motor and gearmotor designs are built in accordance to the following ul insulation class ratings. This is determined by the ambient temperature, the heat generated at fully loaded conditions temperature rise, and the thermal capacity of the motor insulation. May 05, 2016 standard insulation class ratings for groschopps motors and gearmotors may 5, 2016 electric motors are categorized by temperature into groups called insulation classes which rate what temperature a motor can safely run at. Temperature insulation classes give an indication of the maximum temperature that an insulation material may be exposed to without deterioration. The surface temperature of the motor is typically 30c lower than it is at the windings.

The electrical insulation system for wires used in generators, electric motors, transformers, and other wirewound electrical components is divided into different classes by temperature and temperature rise. Maximum ambient temperature minimum ambient temperature. Class a motor slot insulation, made up of paperboard, insulates the motor coil assemblies from ground. The electrical insulation system is sometimes referred to as insulation class or thermal classification. Each 10 o c rise above the rating may reduce the motor lifetime by one half. Nema motor insulation classes describes the ability of motor insulation in the windings to handle heat. The electrical components of a motor must be insulated. During the measurement and immediately afterwards, do not touch any terminals of the motor as some of them carry dangerous voltages that may be fatal. Electric motor efficiency calculate electric motor efficiency. Hot spot c a 105 b f 155 h 220 class a insulation. I n s u l a t i on insulation resistance the insulation resistance is affected by moisture and dirt and therefore a good indicator of deterioration from such cause.

Insulation may be grouped into the following recognised classes. Electrical induction motors synchronous speed the speed at which an induction motor operates depends on the input power frequency and the number of electrical magnetic poles in the motor. Insulation consists of material or combinations of materials such as cotton. As can be seen from the above table, hotspot over temperature allowance for a, b, f and h are respectively 5 c, 10 c, 10 c and 15 c. Groschopps standard motor insulation class ratings. Each 10oc rise above the rating may reduce the motor lifetime by one half. Winding insulation should be checked if the generator has been subjected to any of the following. General motor knowledge part 24 insulation class b2 by lynn r. Insulation class a, previously in use, has been discontinued in view of its low working temperature. Motor insulation class nema standards electrical motor insulation classification. Motor insulation classes temperature rise one important reason for motor failure is the overheating condition. Horizontal and vertical motors, 60 hertz, class b insulation system, totally. Example a motor operating at 180 o c will have an estimated life of. There are many types of insulation materials according to the purpose and the structure.

Jun 01, 2017 temperature insulation classes give an indication of the maximum temperature that an insulation material may be exposed to without deterioration. If a motor is subjected to an ambient temperature higher than 40 o c, it must normally be derated or a higher insulation class of material used. Pdf in order to assess the performances of anpge classf insulation system the. Permissible temperature rise hotspot temperature margin. So the engineer selects the electric motor based on applications. Compliance options ul offers users of eis several ways to. For example, an 80c rise is often referred to as a class b, as 80c is the maximum allowable temperature rise for a 1.

The combination of an ambient temperature of 40c and. The insulation is subjected to heat generated by the motor and must designed to withstand heat generated in a specific application. Insulation class often abbreviated insul class on nameplates, it is an industry standard classification of the thermal tolerance of the motor winding. Insulation class is indicated by a letter designation such as a, b, f or h see table 2, depending on the windings ability. Pdf performance evaluation of a class f electrical insulation. In general a motor should not operate with temperatures above the maximum. At a, the effect of aging and dust accumulation is shown by decreasing values. Drives and automationuseful informationnema insulation classes for motors. Allowable temperature rise is made up of the maximum temperature rise for each insulation class plus a hotspot overtemperature allowance. Accurate motor data will be given on request at the quotation phase. In north america, the national electric manufacturers association nema sets motor standards, including what should go on the nameplate nema standard mg 110. The sharp fall at b indicates there was an insulation fault. The effect of voltage unbalance on the insulation life of a typical tframe motor having class b insulation, running in a 40c ambient, loaded to 100%, is as follows. Small copper wire with 220c insulation is not always available, so insulation systems are limited to 200c note.

Temperature tolerance class b is the most common insulation class used on most 60hz usa motors temperature tolerance class f is the most common for international and 50 hz motors. As can be seen from the above table, hotspot over temperature allowance for a, b. It is the predominant class of insulation used in motor manufacturing today. C in operation above the rated temperature of the class of insulating material. Insulation materials are made to maintain the building components and facilities as long as possible. It is practically impossible to determine rules for the actual minimum insulation resistance value of a motor because resistance varies according to method of construction, condition of insulation material used, rated voltage, size and type. Insulation classes for electric motors learning electrical. Example a motor operating at 180c will have an estimated life of. Motor frames have also been standardized with class e insulation only by iec recommendations, as in table 1.

These voltage spikes can rapidly damage a motor s insulation system, resulting in premature motor failure. Standard insulation class ratings for groschopps motors. The current flowing in the motor originates a temperature rise which in turns degrades the insulation system as per the arrhenius equation for chemical reaction. Temperature tolerance class b is the most common insulation class used on most 60 cycle us motors. To ensure a longer lifetime for the electric motor, the use of thermal sensors is. This practice means that a motor with class f insulation and an 80c rise is referred to as an fb motor. At c, the fault has been repaired rewinding of the motor so the insulation resistance has returned to a. At a, the insulation resistance decreases due to aging and dust accumulation. Association nema to meet motor temperature requirements found in different operating environments. This type of material is used as the solid insulation in oilfilled transformers.

The combination of an ambient temperature of 40c and allowed temperature rise equals the maximum winding temperature of a motor. Temperature tolerance class f is the most common for international and 50 cycle motors. Such cases might arise with motor coupled to oil pump where the load may be increased for short period while pumping cold oil. Insulating will add the comfort to the building, create a healthier home environment, reduce the energy. Small control and potted transformers have insulation systems well below 220c because of the resin used. Insulation classes nema identifies four insulation classes.

To prolong the life of electrical systems and motors, regular insulation resistance testing is required. If the motor is not put into operation immediately upon arrival, it is important to protect it against external factors like moisture, high temperature and impurities in order to avoid damage to the insulation. R, vem uses insulation materials of very high quality to enable operation on converters for output voltages. Electrical insulation systems are rated by standard nema national electrical manufacturers association classifications according to maximum allowable operating temperature. Understanding motor nameplate information nema vs iec. The present frame size assignments are based on class b insulation. Apr 25, 2017 the electrical components of a motor must be insulated. Nema insulation classes do away with guessing, and give the motor manufacturer a defined framework to operate in. Insulation class standards established by the national. Heat kills, and the old standard of using your hand to judge the temperature of a motor and if it was over heating no longer applies.